This product is no longer in stock
Availability date:
Serial Port Access | |
---|---|
Connect directly using Telnet / SSH by port and IP address | |
Connect with EasyPort menu by Telnet / SSH | |
Use an internet browser to access with HTTP or secure HTTPS via EasyPort Web menu | |
Java-free browser access to remote serial console ports via Telnet and SSH | |
Ports can be assigned a specific IP address ( aliasing ) | |
Multisession capability enables multiple users to access ports simultaneously | |
Multihost access enables multiple hosts/servers to share serial ports | |
Accessibility | |
In-band ( Ethernet ) and out-of-band ( dial-up modem ) support | |
Dynamic DNS enables users to find a console server from anywhere on the Internet | |
Domain name control through DHCP option 81 | |
IPV6 and IPV4 addressing support | |
Availability | |
Primary/Backup host functionality enables automatic connections to alternate host(s) | |
Security | |
SSH v1 and v2 | |
SSL V3.0/TLS V1.0, SSL V2.0 | |
SSL Server and SSL client mode capability | |
SSL Peer authentication | |
IPSec VPN : NAT Traversal, ESP authentication protocol | |
Encryption: AES (256/192/128), 3DES, DES, Blowfish, CAST128, ARCFOUR(RC4), ARCTWO(RC2) | |
Hashing Algorithms: MD5, SHA-1, RIPEMD160, SHA1-96, and MD5-96 | |
Key exchange: RSA, EDH-RSA, EDH-DSS, ADH | |
X.509 Certificate verification: RSA, DSA | |
Certificate authority (CA) list | |
Local database | |
RADIUS Authentication, Authorization and Accounting | |
TACACS+ Authentication, Authorization and Accounting | |
LDAP, NIS, Kerberos Authentication | |
RSA SecureID-agent or via RADIUS Authentication | |
SNMP v3 Authentication and Encryption support | |
IP Address filtering | |
Disable unused daemons | |
Active Directory via LDAP | |
Terminal Server | |
Telnet | |
SSH v1 and v2 | |
Rlogin | |
Auto session login | |
LPD, RCP printer | |
MOTD - Message of the day | |
Serial machine to Ethernet | |
Tunnel raw serial data across Ethernet - clear or encrypted | |
Raw serial data over TCP/IP | |
Raw serial data over UDP | |
Serial data control of packetized data | |
Share serial ports with multiple hosts/servers | |
Virtual modem simulates a modem connection - assign IP address by AT phone number | |
Virtual modem data can be sent over the Ethernet link with or without SSL encryption | |
TruePort com/tty redirector for serial based applications on Windows, Linux, Solaris, SCO, HP UX, NCR UNIX and AIX. For a complete list of all the latest drivers click here | |
TrueSerial packet technology provides the most authentic serial connections across Ethernet ensuring serial protocol integrity | |
RFC 2217 standard for transport of serial data and RS232 control signals | |
Customizable or fixed serial baud rates | |
Plug-ins allow customer or Perle provided plug-ins for special applications | |
Software Development Kit ( SDK ) available | |
Serial encapsulation of industrial protocols such as ModBus, DNP3 and IEC-870-5-101 | |
ModBus TCP gateway enables serial Modbus ASCII/RTU device connection to ModBus TCP | |
Data logging will store serial data received when no active TCP session and forward to network peer once session re-established - 32K bytes circular per port | |
Console Management | |
Sun / Oracle Solaris Break Safe | |
Local port buffer viewing - 256K bytes per port | |
External port buffering via NFS, encrypted NFS and Syslog | |
Event notification | |
Manage AC power of external equipment using Perle RPS power management products | |
Clustering - central console server enables access ports across multiple console servers | |
Windows Server 2003/2008 EMS - SAC support GUI access to text-based Special Administrative Console | |
Ping watchdog probes enable customers to power cycle equipment with attached Perle RPS power switches in the event of an unresponsive networking gear | |
Remote Access | |
Dial, direct serial | PPP, PAP/CHAP, SLIP |
HTTP tunneling enables firewall-safe access to remote serial devices across the internet | |
Automatic DNS Update | Utilize DHCP Opt 81 to set IOLAN domain name for easy name management and with Dynamic DNS support , users on the Internet can access the device server by name without having to know its IP address. See Automatic DNS update support for details |
IPSEC VPN client/servers | Microsoft L2TP/IPSEC VPN client ( native to Windows XP) |
Microsoft IPSEC VPN Client ( native to Windows Vista ) | |
Cisco routers with IPSEC VPN feature set | |
Perle IOLAN SDS/STS and SCS models | |
OA&M ( Operations, Administration and Management ) | |
SNMP V3 - read and write, Perle MIB | |
Syslog | |
Perle Device Manager - Windows based utility for large scale deployments | |
Configurable default configuration | |
Installation Wizard | |
Set a Personalized Factory Default for your IOLANs | |
Protocols | |
IPv6, IPv4, TCP/IP, Reverse SSH, SSH, SSL, IPSec/IPv4, IPSec/IPv6, L2TP/IPSec, CIDR, RIPV2/MD5, ARP, RARP, UDP, UDP Multicast, ICMP, BOOTP, DHCP, TFTP, SFTP, SNTP, Telnet, raw, reverse Telnet, LPD, RCP, DNS, Dynamic DNS, WINS, HTTP, HTTPS, SMTP, SNMPV3, PPP, PAP/CHAP, SLIP, CSLIP, RFC2217, MSCHAP |
IOLAN STS4-D | IOLAN STS8-D | |
---|---|---|
Processor | MPC852T, 66 Mhz, 87 MIPS | |
Memory | ||
RAM MB | 32 | - |
Flash MB | 8 | - |
Interface Ports | ||
Number of Serial Ports | 4 | 8 |
Serial Port Interface | RS232 DTE on RJ45 (10 pin) | RS232 DTE on RJ45 (8 pin) |
Sun / Solaris | Sun / Oracle ‘Solaris' Safe - no "break signal" sent during power cycle causing costly server re-boots or downtime |
|
Serial Port Speeds | 50bps to 230Kbps with customizable baud rate support | |
Data Bits | 5,6,7,8, 9-bit protocol support | |
Parity | Odd, Even, Mark, Space, None | |
Flow Control | Hardware, Software, Both, None | |
Serial Port Protection | 15Kv Electrostatic Discharge Protection (ESD) | |
Local Console Port | RS232 on RJ45 with DB9 adapter (provided) | |
Network | 10/100-base TX Ethernet RJ45 | |
Software selectable Ethernet speed 10/100/Auto | ||
Software selectable Half/Full/Auto duplex | ||
Ethernet Isolation | 1.5Kv Magnetic Isolation | |
Power | ||
Power Supply | 120 V AC (USA), 230V AC (International) Wall Power Adaptor included | |
Power Supply Options | Power via External power 9-30v DC, 4.8 Watts uses standard 5.5mm x 9.5mm x 2.1mm barrel socket, Power IN over serial cable |
Power via External power 9-30v DC, uses standard 5.5mm x 9.5mm x 2.1mm barrel socket, |
Nominal Input Voltage | 12v DC | |
Input Voltage Range | 9-30v DC | |
Power IOLAN over Serial | 9-30v DC | N/A |
Power External Device via Serial Port | +5v DC regulated, 1W max | N/A |
Typical Power Consumption @ 12v DC ( Watts ) | 2.4 | 3 |
Indicators | ||
LEDs | Power/System Ready | |
Network Link activity | ||
Serial: Transmit and Receive data per port | ||
Environmental Specifications | ||
Heat Output (BTU/HR) |
8.2 | 10.2 |
MTBF ( Hours )* | 391,199 | 339,967 |
Operating Temperature | 0C to 55C, 32F to 131F | |
Storage Temperature | -40C to 85C, -40F to 185F | |
Humidity | 5 to 95% (non condensing) for both storage and operation. | |
Case | SECC Zinc plated sheet metal (1 mm) | |
Ingress Protection Rating | IP30 | |
Mounting | Wall mount - bracket included | |
DIN Rail bracket optional | ||
Product Dimensions | ||
Weight | 0.36 kg (0.79 lbs) | 0.55 kg (1.2 lbs) |
Dimensions | 11.3 x 8.1 x 2.8 (cm), 4.4 x 3.2 x 1.1 (in) | 11.3 x 15.6 x 2.8 (cm), 4.4 x 6.1 x 1.1 (in) |
Packaging | ||
Shipping Weight | 1.1 kg (2.4 lbs) | 1.3 kg (2.9 lbs) |
Shipping Dimensions | 25.5 x 16.5 x 6.5 (cm), 10.0 x 6.5 x 2.6 (in) | 26 x 6.5 x 17 (cm), 10 x 2.5 x 6.5 (in) |
Regulatory Approvals | ||
Emissions | FCC Part 15, Subpart B, Class A | |
CFR47:2003, Chapter 1, Part 15 Subpart B,(USA) Class A | ||
ICES-003, Issue 4, February 2004 (Canada) | ||
EN55022:1998 + A1:2000 + A2:2003 Class A | ||
EN61000-3-2 : 1995, Limits for Harmonic Current Emissions | ||
EN61000-3-3 : 1995, Limits of Voltage Fluctuations and Flicker | ||
Immunity | EN55024:1998 + A1:2001 + A2:2003 | |
EN61000-4-2: Electrostatic Discharge | ||
EN61000-4-3: RF Electromagnetic Field Modulated | ||
EN61000-4-4: Fast Transients | ||
EN61000-4-5: Surge | ||
EN61000-4-6: RF Continuous Conducted | ||
EN61000-4-8: Power-Frequency Magnetic Field | ||
EN61000-4-11: Voltage Dips and Voltage Interruptions | ||
Safety | IEC 60950-1 : 2005 (2nd Edition) + A1 : 2009 and EN 60950-1 : 2006 + A11 : 2009 |
|
CAN/CSA-C22.2 No. 60950-1-03 and ANSI/UL 60950-1, First Edition April 1st 2003 (Recognized Component) |
||
Other | Reach, RoHS and WEEE Compliant | |
CCATS - G052929 | ||
ECCN - 5A992A | ||
HTSUS Number: 8471.80.1000 | ||
Perle Limited Lifetime Warranty |
Part Code:
04030834