Server Technology STV-4301K Switched Rack PDU

ServerTech ServerTech

New

The Switched Rack PDU STV-4301 with PIPS combines remote configuration and management with power distribution, power monitoring and environmental monitoring. Reboot a single or dual-power server with one command. Receive SNMP alerts when power or environmental conditions exceed thresholds. Assign users specific access rights to designated outlets or groups.


Call For Price And Availability

India: +91 895 697 6186
USA: +1 510 651 2205
Singapore: +65 9152 4003

[email protected]

The Switched Rack PDU STV-4301 with PIPS combines remote configuration and management with power distribution, power monitoring and environmental monitoring. Reboot a single or dual-power server with one command. Receive SNMP alerts when power or environmental conditions exceed thresholds. Assign users specific access rights to designated outlets or groups.

This Sentry PIPS PDU combines all of the features of a Switched PDU with the ability to provide power monitoring per inlet/infeed. Power information per infeed includes current, voltage, power, apparent power, crest factor, reactance, power factor and accumulated energy.

This information replaces branch circuit monitoring devices typically installed in the power distribution panel or remote power panel (RPP) with higher accuracy and lower cost monitoring of each circuit attached to the PDU.

Combine the Sentry PIPS Switched Rack PDU with the Sentry Power Manager software tool to gain power usage information across multiple Rack PDU's individual IP address.

Only our Switched Rack PDU products provide the flexibility needed for all data centers and remote sites; including support for 16/20/30/32-amp power input; 208-240V or European 230V configuration; UL 60950-1 branch circuit protection; EN 60950-1:2001; SSL & SSH security; and SNMP-based input current monitoring. For cabinets with mid-density servers, this cabinet distribution unit delivers unparalleled remote management solutions.

Remote Power Control
Individual or group outlet remote power control to cycle power and reboot any selected server(s) or other network device(s). Use TCP/IP (HTTP, HTTPS, SSH, Telnet, SNMP) or RS-232 to communicate with each Sentry Cabinet PDU and rectify locked-up network devices. Assign outlets to a group for control of dual-power supply servers and other gear with a single command. Create an unlimited number of groups with any combination of outlets associated to each group. Reduce Mean Time to Repair (MTTR) a failing server by controlling individual power outlet receptacles to reboot any selected server or other device.

HTTP/HTTPs Web Configuration & Control
Use the Sentry Web interface to configure each unit, including network settings, outlet naming & grouping, SNMP traps for environmental & power thresholds and firmware updates. Also use the Web interface to control individual or group outlets and monitor key values, including amperage load(s), temperature/humidity and other environmental conditions. SSL security provides a secure HTTPs connection.

SNMP Management & Event Notification
The Sentry family of products supports the Simple Network Management Protocol (SNMP). This allows network management systems to use SNMP requests to retrieve information and control power for the individual outlets. The Sentry includes an SNMP v1 agent supporting standard MIB I and MIB II objects. A private enterprise MIB extension (Sentry3 MIB) is also supported to provide remote power control. SNMP traps can be generated for various events, including Input Current Load Thresholds (min & max), Temperature Thresholds (min & max), Humidity Thresholds (min & max), water indication, closed contacts (cabinet doors open/close), as well as notification of any time an outlet status is changed (on/off).

Add a Second Tower
Connect an Expansion Cabinet PDU to any Switched Cabinet PDU to control two power input circuits and manage outlets (individual or groups) under 1 IP address - our exclusive strategy for managing dual power-supply servers.

Zero U Enclosure
A vertical enclosure that occupies Zero Vertical U of rack space in the equipment cabinet. It mounts on the back rails or in the cavity space of the cabinet.

Secure Access - SSH or SSL Protection
Secure Shell (SSH), known as Secure Socket Shell, is a Unix-based command interface and protocol for securely getting access to a remote device. Sentry supports SSHv2. Secure Sockets Layer (SSL) is a commonly-used protocol for managing the security of a message transmission on the Internet. SSL is an integral part of most Web browsers (clients) and Web servers. Sentry supports SSLv3/TLSv1.

Integrated Temp/Humidity Probes
Two (2) RJ-style connectors located on the face panel of the PDU's enclosure provide support for two (2) Integrated Temperature & Humidity Probes with ten-foot (10') cables provide real-time measurements in the data center cabinet.

Firmware Flash Upgradeable
Access new firmware updates via FTP for new firmware features and code releases. An update to the firmware does not affect the status of the power outlets.

LDAP/LDAPS
The sentry family of products supports Lightweight Directory Access Protocol (LDAP) Version 3 including LDAPS (LDAP over TSL/SSL). This support enable authentication with LDAP servers; user accounts do not need to be individually created locally on each Sentry device. 
This allows administrators to pre-define and configure (in each Sentry product, and in the LDAP server) a set of necessary LDAP groups, and access rights for each. User's access rights can then be assigned or revoked simply by making the user a member of one or more pre-defined Sentry LDAP groups. User account can be added, deleted, or changed in the LDAP server without any changes on individual Sentry products. 
Sentry LDAP support has been tested in the following environments: 
- Microsoft Active Directory (MSAD) 
- Novell eDirectory (eDir) 
- Open LDAP

Load Sense
Individual input current monitoring ("Load Sense") provides real-time power measurement of the load in amps on each power inlet, accessible via firmware interface.

RS-232 Control
Serial control via any device with a bi-directional serial port, including a PC, laptop, KVM switch, Console Port Access switch, or terminal server.

24-Character Outlet Receptacle Names
Use the firmware interface (Web or serial) to edit individual outlet receptacles. Identify each receptacle with the device's serial number, IP address, asset allocation #, department or any other method to individually name outlets.

Sentry Rack PDU Specifications
Item # Available Input 
Voltages
Rated Amperage Available Input Cord Outlets Dimensions 
(L x W x D)*
STV-4301 (48xC13) 1Ph with PIPS
STV-4301A 
SEV-4301A*
208-240V 
50/60Hz
20A IEC 60320/C20 Power Inlet, Top Entry 

(48) IEC 60320/C13 

69.0 x 3.25 x 2.25 in. 
(1753 x 83 x 57 mm)
STV-4301C 
SEV-4301C*
208-240V 
50/60Hz
30A
NEMA L6-30P Plug, 10'(3m) Top Cord Entry
(48) IEC 60320/C13 

69.0 x 3.25 x 2.25 in. 
(1753 x 83 x 57 mm)
STV-4301D 
SEV-4301D*
230V 
50/60Hz
16A
IEC 60320/C20 Power Inlet, Top Entry 

(48) IEC 60320/C13 

69.0 x 3.25 x 2.25 in. 
(1753 x 83 x 57 mm)
STV-4301K 
SEV-4301K*
230V 
50/60Hz
32A
IEC Blue 2P+G Plug 10'(3m) Top Cord Entry

(48) IEC 60320/C13 

69.0 x 3.25 x 2.25 in. 
(1753 x 83 x 57 mm)
* SEV refers to the Expansion Module
Power Cord Options
> PTCORD-1 IEC 60320/C19 - NEMA L6-20P (20A Twist-Lock) 10? (3m) 
> PTCORD-2 IEC 60320/C19 - Schuko 10? (3m) 
> PTCORD-3 IEC 60320/C19 - IEC 60309 (BS4343, CEE17) 16/20A Blue (UK Commando) 10? (3m) 
> PTCORD-4 IEC 60320/C19 - BS1363 13A (UK) 10? (3m)

Part Code:

STV-4301K

Write a review

Server Technology STV-4301K Switched Rack PDU

Server Technology STV-4301K Switched Rack PDU

The Switched Rack PDU STV-4301 with PIPS combines remote configuration and management with power distribution, power monitoring and environmental monitoring. Reboot a single or dual-power server with one command. Receive SNMP alerts when power or environmental conditions exceed thresholds. Assign users specific access rights to designated outlets or groups.