Server Technology CX-24V4K415A1 Switched CDU

ServerTech ServerTech

New

The Switched CDU combines remote configuration and management with power distribution and power and environmental monitoring. Reboot a single or dual-power server with one command. Receive SNMP or email-based alerts when power or environmental conditions exceed thresholds. 


Call For Price And Availability

India: +91 895 697 6186
USA: +1 510 651 2205
Singapore: +65 9152 4003

[email protected]

The Switched CDU combines remote configuration and management with power distribution and power and environmental monitoring. Reboot a single or dual-power server with one command. Receive SNMP or email-based alerts when power or environmental conditions exceed thresholds. Assign user specific access rights to designated outlets or groups. This Switched CDU provides the flexibility needed for all data centers and remote sites, including power requirements for high-amp, high voltage; UL 60950-1 branch circuit protection; SSL & SSH security; and SNMP-based input current monitoring.

High Density
Single-power input feed; 24 outlets per enclosure (Qty 18 IEC C13 & qty 6 IEC C19 outlets) High Power Distribution
3-Phase 400V power option 16-Amp and 32-Amp power input feed options.

Remote Power Management:
Power cycle individual power outlets, or groups of power outlets, to remotely reboot servers and network devices, anywhere  in the world. Or, power-off unused power receptacles

IP Access & Security
Web interface, SSL, SSH, Telnet, SNMP, FTP, SNTP, Syslog, LDAP, LDAPS, TACACS and RS-232 access
SNMP Traps and Email alerts Provide automated alerts for power and environmental conditions.

Environmental Monitoring:
Each Switched CDU supports two external temperature & humidity probes and reports conditions thru the user interface  without the need for additional IP addresses.

Add an Expansion Module
Daisy chain the Switched CDU Expansion Module (CW/CX) for power monitoring of separate power circuits from a single IP
address.

Sentry Cabinet PDU Specifications
Item # Available Input 
Voltages
Rated Amperage Available Input Cord Outlets Dimensions 
(L x W x D)*
CW-16V2/VE
CW-16V2A317 
CX-16V2A317*
208-240V 
50/60Hz
20A IEC C20 Inlet, Bottom Entry (16) IEC 60320/C13 49.50" x 1.75" x 2.25" 
(1257x44.4x57 mm)
CW-16V2C317 
CX-16V2C317*
208-240V 
50/60Hz
30A NEMA L6-30P Plug, 10'(3m), Bottom Cord (16) IEC 60320/C13 49.50" x 1.75" x 2.25" 
(1257x44.4x57 mm)
CW-16VEA317 
CX-16VEA317*
230V 
50/60Hz
16A
IEC C20 Inlet, Bottom Entry
(16) IEC 60320/C13 49.50" x 1.75" x 2.25" 
(1257x44.4x57 mm)
CW-16VEK317 
CX-16VEK317*
230V 
50/60Hz
32A IEC Blue 2P+G Plug, 10'(3m), Bottom Cord (16) IEC 60320/C13 49.50" x 1.75" x 2.25" 
(1257x44.4x57 mm)
* CX refers to the Expansion Module
 

Part Code:

CX-24V4K415A1

Write a review

Server Technology CX-24V4K415A1 Switched CDU

Server Technology CX-24V4K415A1 Switched CDU

The Switched CDU combines remote configuration and management with power distribution and power and environmental monitoring. Reboot a single or dual-power server with one command. Receive SNMP or email-based alerts when power or environmental conditions exceed thresholds.