The Switched CDU combines remote configuration and management with power distribution and power and environmental monitoring. Reboot a single or dual-power server with one command. Receive SNMP or email-based alerts when power or environmental conditions exceed thresholds.
This product is no longer in stock
Availability date:
The Switched CDU combines remote configuration and management with power distribution and power and environmental monitoring. Reboot a single or dual-power server with one command. Receive SNMP or email-based alerts when power or environmental conditions exceed thresholds. Assign user specific access rights to designated outlets or groups. This Switched CDU provides the flexibility needed for all data centers and remote sites, including power requirements for high-amp, high voltage; UL 60950-1 branch circuit protection; SSL & SSH security; and SNMP-based input current monitoring.
High Density
Single-power input feed; 24 outlets per enclosure (Qty 18 IEC C13 & qty 6 IEC C19 outlets) High Power Distribution
3-Phase 400V power option 16-Amp and 32-Amp power input feed options.
Remote Power Management:
Power cycle individual power outlets, or groups of power outlets, to remotely reboot servers and network devices, anywhere in the world. Or, power-off unused power receptacles
IP Access & Security
Web interface, SSL, SSH, Telnet, SNMP, FTP, SNTP, Syslog, LDAP, LDAPS, TACACS and RS-232 access
SNMP Traps and Email alerts Provide automated alerts for power and environmental conditions.
Environmental Monitoring:
Each Switched CDU supports two external temperature & humidity probes and reports conditions thru the user interface without the need for additional IP addresses.
Add an Expansion Module
Daisy chain the Switched CDU Expansion Module (CW/CX) for power monitoring of separate power circuits from a single IP
address.
Sentry Cabinet PDU Specifications | |||||
Item # | Available Input Voltages |
Rated Amperage | Available Input Cord | Outlets | Dimensions (L x W x D)* |
CW-16V2/VE | |||||
CW-16V2A317 CX-16V2A317* |
208-240V 50/60Hz |
20A | IEC C20 Inlet, Bottom Entry | (16) IEC 60320/C13 | 49.50" x 1.75" x 2.25" (1257x44.4x57 mm) |
CW-16V2C317 CX-16V2C317* |
208-240V 50/60Hz |
30A | NEMA L6-30P Plug, 10'(3m), Bottom Cord | (16) IEC 60320/C13 | 49.50" x 1.75" x 2.25" (1257x44.4x57 mm) |
CW-16VEA317 CX-16VEA317* |
230V 50/60Hz |
16A | IEC C20 Inlet, Bottom Entry |
(16) IEC 60320/C13 | 49.50" x 1.75" x 2.25" (1257x44.4x57 mm) |
CW-16VEK317 CX-16VEK317* |
230V 50/60Hz |
32A | IEC Blue 2P+G Plug, 10'(3m), Bottom Cord | (16) IEC 60320/C13 | 49.50" x 1.75" x 2.25" (1257x44.4x57 mm) |
* CX refers to the Expansion Module | |||||
|
Part Code:
CX-24V4K415A1