The Switched CDU combines network configuration and management with power distribution, environmental monitoring and the ability to provide power monitoring per an individual outlet/device. Power information per outlet includes current, voltage, power (kW), apparent power (VA), crest factor and power factor. Reboot a single or dual-power server with one command. Receive SNMP or email-based alerts when power or environmental conditions exceed thresholds. Assign user specific access rights to designated outlets or groups.
This product is no longer in stock
Availability date:
The Switched CDU combines network configuration and management with power distribution, environmental monitoring and the ability to provide power monitoring per an individual outlet/device. Power information per outlet includes current, voltage, power (kW), apparent power (VA), crest factor and power factor. Reboot a single or dual-power server with one command. Receive SNMP or email-based alerts when power or environmental conditions exceed thresholds. Assign user specific access rights to designated outlets or groups.
This Switched CDU has top entry for network, serial & environmental connections combined with a bottom power cord entry. Current monitors are easily inverted via the web GUI or serial interface. This provides flexibility when connecting Switched CDU’s to overhead power or busways.
High Density:
Single-power input feed; 24 outlets per enclosure (Qty 12 IEC C13 & 12 IEC C19 outlets).
Power Distribution:
240/415V 3-phase, 20/30A power input feed option with 240V output.
Input Current Monitor:
Precisely measure the aggregate current draw (in amps) of each phase of the circuit. On-site verification of the input current with LED digital display. Remote verification via web browser or serial screen.
Networked Power Management:
Power cycle individual power outlets, or groups of power outlets, to remotely reboot servers and network devices, anywhere in the world. Or, power-off unused power receptacles.
IP Access & Security:
Web interface, SSL, SSH, Telnet, SNMP, FTP, SNTP, Syslog, LDAP, LDAPS, TACACS, RADIUS, and RS-232 access.
SNMP Traps and Email alerts:
Provide automated alerts for power and environmental conditions.
Environmental Monitoring:
Each Switched CDU supports two external temperature & humidity probes and reports conditions through the user interface without the need for additional IP addresses.
Add an Expansion Module:
Daisy chain the Switched CDU Expansion Module (CXG) for power monitoring of separate power circuits from a single IP address.
Sentry Cabinet PDU Specifications | |||||
Item # | Available Input Voltages |
Rated Amperage | Available Input Cord | Outlets | Dimensions (L x W x D) |
CWG-24V5 (12xC13 & 12xC19) - 415V 3Ph | |||||
CWG-24V53458A9 CXG-24V53458A9* |
240/415V 3-Phase Wye, 50/60Hz |
20 A | IEC Red 6hr 3P+N+G Plug, 10'(3m), Top Cord Entry | (12) IEC 60320/C13 (12) IEC 60320/C19 |
1753 x 44.4 x 88.9 mm. [69.0 x 1.75 x 3.50 in.) |
CWG-24V54458A9 CXG-24V54458A9* |
240/415V 3-Phase Wye, 50/60Hz |
30 A | IEC Red 6hr 3P+N+G Plug, 10'(3m), Top Cord Entry | (12) IEC 60320/C13 (12) IEC 60320/C19 |
1753 x 44.4 x 88.9 mm. [69.0 x 1.75 x 3.50 in.) |
CWG-24V5Z458A9 CXG-24V5Z458A9* |
240/415V 3-Phase Wye, 50/60Hz |
30 A | NEMA L22-30P Plug, 10'(3m), Top Cord Entry | (12) IEC 60320/C13 (12) IEC 60320/C19 |
1753 x 44.4 x 88.9 mm. [69.0 x 1.75 x 3.50 in.) |
* CXG refers to the Expansion Module |
Part Code:
CWG-24V5Z458A9