The Raritan PX2-5000 family of high-quality rack power distribution units (PDUs) offers real-time remote unit-level and individual outlet-level switching and power monitoring of current (amps), voltage, power (kVA, kW), power factor and energy consumption (kWh) with ISO/IEC +/- 1% billing-grade accuracy.
This product is no longer in stock
Availability date:
The Raritan PX2-5000 family of high-quality rack power distribution units (PDUs) offers real-time remote unit-level and individual outlet-level switching and power monitoring of current (amps), voltage, power (kVA, kW), power factor and energy consumption (kWh) with ISO/IEC +/- 1% billing-grade accuracy. The PX-5000 also supports Raritan’s plug-and-play environmental sensors. Users can define thresholds and receive alerts when thresholds are crossed for both power and environmental events.
Also locking ready capable sockets when used with Raritan's compatible locking cables.
The PX2-5000 series is available in Zero U (vertical mount) and 1U and 2U (horizontal mount) form factors with a wide variety of NEMA, IEC and other plugs and receptacles, including models that support high power distribution such as 400V. Precise power information can be monitored, and the PX-5000 configured, via a user-friendly Web browser GUI or command line interface. Power information is also displayed at the PDU locally. Security is ensured with up to 256-bit encryption, strong passwords and advanced authorization options, including permissions, LDAP/S and Active Directory®. Plus the PX-5000 series is fully compatible with Raritan's Power IQ energy management software solutions
Voltage (V), Current (A), Active Power (kW), Real Power (kVA), Energy (kWh), Power
Metering Accuracy : ISO/IEC 62053-21 1%
Metering per Input Line : Yes
Metering per Branch Circuit Breaker : Yes
Metering per Output Receptacle : Yes
Remote Outlet Switching : Yes
Environmental Sensor Ready : Yes
10/100 BaseT Ethernet. Optional WiFi (802.11a/b/g/n)
HTTP(s); SSH; Telnet; RS-232 (Serial); Power IQ; SNMP version v2/v3; SMTP; JSON-RPC
Cascading : Yes
Max 8 PDUs can be daisy chained using a single Ethernet connection Onboard Display 3-digit user-selectable display (can be selected between Manual and Auto Display Mode).
Can display Line voltage, Line current, CB Current (if IPDU supports CB), Unit active power, Outlet Voltage, Outlet Current, and Outlet Active power.
Temperature, Humidity, Air Flow, Static Pressure
Single cable connection provides temp/humidity monitor
Raritan PX2-5152R 1PH, 230V AC, 32A, 8 outlets: 6 x BS1363, 2 x IEC C-19, plug: IEC60309 32A, 7.36kVA, 2U horizontal PDU, Ethernet, serial USB-A, USB-B and sensor connections
INPUT
Input Plug : IEC 60309 2P+E 6h 32A 2P3W (L1/L2/E) IP44("splashproof") (230V, Single phase)
Cord Length : 3 meters (9.84 feet) standard
Cord Entry : Rear feed
Cable Type : 2P 3W
Number of Power Cords : 1
Maximum Input Current : 32A (per line)
Nominal Input Voltage : 230V, Single phase
Rated Input Voltage : 200 - 240V, Single phase
Input Frequency : 50/60Hz
Power Capacity : 6.4kVA at 200V, 7.7kVA at 240V
OUTPUT
Nominal Output Voltage : 230V
Rated Output Voltage : 200 - 240V
Output Connections :
a. (6) BS1363; 13A
b. (2) IEC 60320 C19 2-pole, 3-wire; 16A
Overload Protection : N/A
Part Code: