New
APC Metered by Outlet with Switching Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and individual outlet power metering. Remote outlet level controls allow power on/off functionality for power recycling to reboot locked-up equipment and to avoid unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads.
This product is no longer in stock
Availability date:
APC Metered by Outlet with Switching Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and individual outlet power metering. Remote outlet level controls allow power on/off functionality for power recycling to reboot locked-up equipment and to avoid unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, and locking IEC receptacles. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by Struxureware for Data Centers using Data Center Expert and Data Center Operations with Capacity and Change modules.
Metering-by-Outlet capability
Individual outlet level power metering provides a more granular view of the power distributed to equipment within the enclosure. It also provides the ability to analyze component power trends and perform capacity planning.
Output | |
Nominal Output Voltage
|
100V, 120V |
Output Connections | (24) NEMA 5-20R |
Overload Protection
|
Yes |
Input | |
Nominal Input Voltage
|
100V, 120V |
Input Frequency | 50/60 Hz |
Regulatory Derated Input Current (North America) | 24A |
Input Connections | NEMA L5-30P |
Cord Length | 3.05 meters |
Number of Power Cords | 1 |
Acceptable Input Voltage | 100-120 VAC |
Maximum Input Current per phase | 30A |
Load Capacity | 2880 VA |
Physical | |
Net Weight
|
8.05 KG |
Maximum Height | 1829.00 mm |
Maximum Width | 55.00 mm |
Maximum Depth | 51.00 mm |
Shipping Weight | 10.13 KG |
Shipping Height | 2041.00 mm |
Shipping Width | 164.00 mm |
Shipping Depth | 119.00 mm |
Color | Black |
Environmental | |
Operating Environment
|
-5 - 45 °C |
Operating Relative Humidity | 5 - 95% |
Operating Elevation | 0-3000 meters |
Storage Temperature | -25 - 65 °C |
Storage Relative Humidity | 5 - 95% |
Storage Elevation | 0-15000 meters |
Conformance | |
Regulatory Approvals
|
cUL Listed, FCC Part 15 Class A, ICES-003, PSE, UL 60950-1, UL Listed |
Standard Warranty | 2 years repair or replace |
Sustainable Offer Status | |
RoHS
|
Compliant |
REACH | REACH: Contains No SVHCs |
Battery Directive | Compliant |
Battery Notes | Contains Lithium Coin Cell |
Part Code:
AP8641