APC Metered by Outlet with Switching Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and individual outlet power metering. Remote outlet level controls allow power on/off functionality for power recycling to reboot locked-up equipment and to avoid unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding.
This product is no longer in stock
Availability date:
APC Metered by Outlet with Switching Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and individual outlet power metering. Remote outlet level controls allow power on/off functionality for power recycling to reboot locked-up equipment and to avoid unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, and locking IEC receptacles. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager.
Output | |
Nominal Output Voltage
|
230V |
Output Connections | (21) IEC 320 C13 (3) IEC 320 C19 |
Overload Protection
|
No |
Maximum Total Current Draw per Phase
|
16A |
Input | |
Nominal Input Voltage
|
200V, 208V, 230V |
Input Frequency | 50/60 Hz |
Input Connections | IEC 309 16 A 2P+E |
Acceptable Input Voltage | 100-240 VAC |
Maximum Input Current per phase | 10A |
Cord length | 3 Meters |
Physical | |
Net Weight
|
6.77 KG |
Maximum Height | 1829.00 mm |
Maximum Width | 56.00 mm |
Maximum Depth | 51.00 mm |
Shipping Weight | 9.05 KG |
Shipping Height | 2038.00 mm |
Shipping Width | 162.00 mm |
Shipping Depth | 117.00 mm |
Color | Black |
Environmental | |
Operating Environment
|
-5 - 45 °C |
Operating Relative Humidity | 5 - 95% |
Operating Elevation | 0-3000 meters |
Storage Temperature | -25 - 65 °C |
Storage Relative Humidity | 5 - 95% |
Storage Elevation | 0-15000 meters |
Conformance | |
Regulatory Approvals
|
cUL Listed, FCC Part 15 Class A, ICES-003, PSE, UL 60950-1, UL Listed |
Standard Warranty | 2 years repair or replace |
Sustainable Offer Status | |
RoHS
|
Compliant |
REACH | REACH: Contains No SVHCs |
Battery Directive | Compliant |
Battery Notes | Contains Lithium Coin Cell |