Server Technology CW-24VDD311A1/CX-24VDD311A1* intelligent PDU

ServerTech ServerTech

New

The Switched CDU’s combine remote conguration and management with power distribution and power and environmental monitoring. Reboot a single or dual-power server with one command. Receive SNMP or email-based alerts when power or environmental conditions exceed thresholds. Assign users specic access rights to designated outlets or groups.

 


Call For Price And Availability

India: +91 895 697 6186
USA: +1 510 651 2205
Singapore: +65 9152 4003

[email protected]

The Switched 24VD/VY(C13-C19)-3Ph PDU combines remote configuration and management with power distribution, power monitoring and environmental monitoring. Reboot a single or dual-power server with one command. Receive SNMP alerts when power or environmental conditions exceed thresholds. Assign users specific access rights to designated outlets or groups. Choose one power distribution unit for your high-density cabinets.
Only our Switched CDU products provide the flexibility needed for all data centers and remote sites, including power requirements for high-amp, high voltage; UL 60950-1 branch circuit protection; SSL & SSH security; and SNMP-based input current monitoring.

  • Mid and High Density: Single-power input feed; 24 outlets per enclosure (Qty 18 IEC C13 & qty 6 IEC C19 outlets)
  • High Power Distribution: 208-240V 3-Phase Delta and Wye power options; 20 and 30-Amp power input feed option.
  • Input Current Monitor: Precisely measure the aggregate current draw (in amps) on each power circuit. On-site veri­cation of the input current with the LED digital display. Remote veri­cation via web browser or serial screen.
  • Remote Power Management:Power cycle individual power outlets, or groups of power outlets, to remotely reboot servers and network devices, anywhere in the world. Or, power-o‑ unused power receptacles
  • IP Access & Security: Web interface, SSL, SSH, Telnet, SNMP, FTP, SNTP, Syslog, LDAP, LDAPS, TACACS and RS-232 access
  • SNMP Traps and Email alerts: Provide automated alerts for power and environmental conditions
  • Environmental Monitoring: Each Switched CDU supports two external temperature & humidity probes and reports conditions thru the user interface without the need for additional IP addresses
  • Add an Expansion Module: Daisy chain the Switched CDU Expansion Module (CW/CX) for power monitoring of separate power circuits from a single IP address

Item  

Input Voltage

 Read Amperage

Availble input Cord

           Outlets

      Dimensions

CW-24VDD311A1
CX-24VDD311A1*

3-Phase Delta, 208V
50/60 Hz

                20A

NEMA L15-20P Cordset, 10ft (3m) (18) IEC 60320/C13
(6) IEC 60320/C19
69.0x1.75x 2.25in.
(1753x44x57mm)

Part Code:

CW-24VDD311A1/CX-24VDD311A1*

Write a review

Server Technology CW-24VDD311A1/CX-24VDD311A1* intelligent PDU

Server Technology CW-24VDD311A1/CX-24VDD311A1* intelligent PDU

The Switched CDU’s combine remote conguration and management with power distribution and power and environmental monitoring. Reboot a single or dual-power server with one command. Receive SNMP or email-based alerts when power or environmental conditions exceed thresholds. Assign users specic access rights to designated outlets or groups.