  • Metered C42V-5 415V Alternating Phase 20/30A 36xC13 & 6xC19
  • Unique high density Metered power distribution with Alternating phase outlets
  • 10KAIC circuit protection
  • Zero-U button and bracket mounting  options

 

 


Call For Price And Availability

India: +91 895 697 6186
USA: +1 510 651 2205
Singapore: +65 9152 4003

[email protected]

Designed for customers looking for a high density mixed outlet solution for 240/415V power.  The CS42VY-5 provides patent pending alternating phase power distribution to simplify load balancing and reduce the cord length from the server to the CDU.  
The Sentry Cabinet Power Distribution Unit (CDU) is an intelligent PDU with local LED input current monitoring, allowing network engineers to utilize the Cabinet PDU's True RMS Power Monitor to precisely measure the current (in amps) that network devices are drawing on the power circuit. As new equipment units are added to the power drop, immediately observe its impact on the cumulative current draw. This allows the engineer to safely load each circuit to its maximum allowable load capacity without the danger of overloading the power circuit.
The Cabinet PDU meets new UL 60950-1 Branch Circuit Protection requirements. Each branch circuit utilizes a Circuit Breaker as an Overcurrent Protection Device (OCPD). The Circuit Breaker is rated to 10 KAIC ( Thousand Amp Interrupt Capacity) to provide additional protection in the event of a short circuit failure at the rack.

  • Input Current Monitor: Precisely measure the  aggregate current draw (in amps) on each phase of the power circuit. On-site  verification of the input current with the LED digital display.
  • Power Distribution: 415V,3-Phase Wye, 20 and 30 Amp Power Input
  • High-Density Power Distribution: (36) IEC 60320 C13 and (6) IEC 60320 C19  outlets per enclosure
  • Branch Circuit Protection:Sentry CDUs meet UL 60950-1 requirements
  • Vertical Mounting: Zero-U button and bracket mounting  options

Item  

  Input Voltage

     Read Amperage

Availble input Cord

           Outlets

      Dimensions

         C42VY-5CAF21C4

240/415V 3-Phase Wye 50/60Hz

                30A

NEMA L22-30P Plug, 10

'(3m), Bottom/Frt Entry

     (36) IEC 60320/C13

       (6) IEC 60320/C19

      69.0 x 2.2 x 2.2 in.

      (1753 x 56 x 56 mm)

Part Code:

C42VY-5CAF21C4