The Sentry 48DCXB-04-4X070-DONB Intelligent PDU and Remote Power Manager minimizes the impact of locked-up routers, servers and other network devices on business-critical networks. CLECs, ILECs, ISPs and enterprises use the Sentry 48DCXB-04-4X070-DONB to manage equipment in remote sites, co-location facilities and network operation centers. Sentry 48DCXB-04-4X070-DONB eliminates the need to dispatch a field service technician for manual intervention when devices lock-up. Using a Sentry 48DCXB-04-4X070-DONB, the network operations center can quickly restart locked-up remote network servers to ensure that the network is fully operational around the clock.
This product is no longer in stock
Availability date:
The Sentry 48DCXB-04-4X070-DONB Intelligent PDU and Remote Power Manager minimizes the impact of locked-up routers, servers and other network devices on business-critical networks. CLECs, ILECs, ISPs and enterprises use the Sentry 48DCXB-04-4X070-DONB to manage equipment in remote sites, co-location facilities and network operation centers. Sentry 48DCXB-04-4X070-DONB eliminates the need to dispatch a field service technician for manual intervention when devices lock-up. Using a Sentry 48DCXB-04-4X070-DONB, the network operations center can quickly restart locked-up remote network servers to ensure that the network is fully operational around the clock.
Sentry 48 VDC PDUs provide immediate operational cost savings, including:
> Reduced field service visits
> Improved problem/solution response time
> Improved network availability
> Improved facility security
Eliminate the Need for a Separate Power Distribution Panel
> The Sentry 48DCWB-04-4X070-DONB is an intelligent unit that combines the functions of a power distribution panel and remote power management unit into a 2.5U 19"rack-mounted enclosure.
> Each power output terminal connection is rated to switch 70 amps and is protected by interchangeable TPC fuses allowing for the current rating to be adjusted onsite.
Measurement Features
> Use RS-232 and/or TCP/IP to monitor the status of key measurement values. Receive SNMP or email alerts as well as Syslog when a measurement value is out of a predefined threshold.
Input Feed/Outlet "On Sense" - Verifies power at each power input/outlet connection.
Load Sense - Provides an accurate, real time measurement of the current draw, in amps, for each power outlet.
Environmental Sensors - Supports two external probes that each measure temperature and humidity.
Sentry Cabinet PDU Specifications | |||||
Item # | Input | Rated Amperage | Low Current Outputs |
High Current Outputs |
Dimensions (W x H x D)*** |
-48V Switched 4x70A Inputs/ 4x70A Outputs |
|||||
48DCWB-04-4X070-DONB 48DCXB-04-4X070-DONB* |
(4) -48VDC (-40 to -60) Input Terminal Blocks (+/- & G) |
70A each, 280A total |
None |
4) 70A max outlets protected with TPC fuses (75A max)** |
2.5U, 17" x 4.4" x 16" (432 x 112 x 407mm)*** |
*Expansion PDU **Available TPC Fuse Values: 10, 15, 20, 25, 30, 40, 50, 60, 75 amp ***Dimensions exclude the 19" standard mounting brackets included with PDU |
Part Code:
48DCXB-04-4X070-DONB