Raritan PX2-5098R iPDU

Raritan Raritan

New

Raritan PX2-5098R - 3PH Wye, 400V AC, 32A, 2 outlets: 2 x IEC 60309 32A 3P+N+PE, plug: IEC 60309 32A 3P+N+PE, 22.2kVA, 3U horizontal PDU, Ethernet, serial, USB-A, USB-B and sensor connections.


Call For Price And Availability

India: +91 895 697 6186
USA: +1 510 651 2205
Singapore: +65 9152 4003

[email protected]

Raritan PX is an intelligent power distribution unit (PDU) that allows you to reboot remote servers and other
network devices and/or to monitor power in the data center.
The intended use of the Raritan PX is distribution of power to information technology equipment such as computers and communication equipment where such equipment is typically mounted in an equipment rack located in an information technology equipment room.
Raritan offers different types of PX units -- some are outlet-switching capable, and some are not. With the outlet-switching function, you can recover systems remotely in the event of system failure and/or system lockup, eliminate the need to perform manual intervention or dispatch field personnel, reduce downtime and mean time to repair, and increase productivity.

Energy Metering:Voltage (V), Current (A), Active Power (kW), Real Power (kVA), Energy (kWh), Power Factor
Metering Accuracy:ISO/IEC 62053-21 1%
Metering per Input Line:Yes
Metering per Branch Circuit Breaker:Yes
Metering per Output Receptacle:Yes
Remote Outlet Switching:Yes
Environmental Sensor Ready:Yes
Networking:10/100 BaseT Ethernet. Optional WiFi (802.11a/b/g/n)
Remote Management:HTTP(s); SSH; Telnet; RS-232 (Serial); Power IQ; SNMP version v2/v3; SMTP; JSON-RPC
Cascading:Yes, Max 8 PDUs can be daisy chained using a single Ethernet connection
Onboard Display:
3-digit user-selectable display (can be selected between Manual and Auto Display Mode).
Can display Line voltage, Line current, CB Current (if IPDU supports CB),  Unit active power, Unbalanced Current percentage (if 3 phase IPDU), Outlet Voltage, Outlet Current, and Outlet Active power
Compatible Sensors:
Temperature, Humidity, Air Flow, Static Pressure
Single cable connection provides temp/humidity monitoring
at three points in cabinet (with a single sensor assembly)

Inputs 400V, 32A
Phase   Three-Phase Wye
Form Factors   3 U
IEC  2 x IEC60309 32A 3P+N+PE, plug:IEC60309 32A 3P+N+PE
Outlets  2
Voltage   400V

 

22.2kVA, 3U horizontal PDU, Ethernet, serial, USB-A, USB-B and sensor connections.

Part Code:

PX2-5098R 