Cyber Power PDU20MHVIEC10AT 10-outlet (rear) metered

Cyber Power Cyber Power

New

  • Metered Auto Transfer Switch (ATS) PDU
  • Digital Display (Load, Voltage, and KW)
  • 2 x IEC-320 C20 Plugs for Redundancy
  • 10 IEC-320 (8) C13 / (2) C19 Outlets (10 Rear)
  • 200-240V AC - 50/60Hz - 20-amp electrical capacity
  • 1U rack mount


Call For Price And Availability

India: +91 895 697 6186
USA: +1 510 651 2205
Singapore: +65 9152 4003

[email protected]

The CyberPower PDU20MHVIEC10AT, 10-outlet 1U rack mount metered auto transfer switch (ATS) power distribution unit (PDU), provides 200-240V / 20A output. The PDU distributes unfiltered electrical pass-through to 10 IEC-320 (8) C13 / (2) C19 receptacles from redundant IEC-320 C20 plugs. Dual power cords can be plugged into separate power sources to provide redundancy to single-corded connected equipment. If power for the primary source exceeds the lower or upper thresholds, or if power fails, the PDU will switch to the secondary power source to ensure continuous operation. The PDU will switch back to the primary power source when incoming power becomes stable.

The LCD provides local monitoring of the PDU. Perform load management by using the display to measure the electrical current (displayed in amperes) used by connected equipment. The LCD can also display input and output voltages, to diagnose potential issues with input AC power. Active power consumption (displayed in kilowatts) and hardware and firmware versions are also viewable on the LCD screen.

The PDU20MHVIEC10AT includes a SNMP/HTTP card slot for adding an RMCARD202 or RMCARD203 (sold separately). With the addition of the SNMP card and an IP address on the network interface, users have real-time monitoring of the ATS PDU. The CyberPower Management Console provides real-time remote monitoring of PDU vitals and event logging to review historical power conditions, such as input voltages, load levels, and outlet status. Automatic event notifications can be sent to designated users when power events occur, via Email, SMS Text, or SNMP Trap.

Designed for datacenters and other demanding electrical applications, the PDU20MHVIEC10AT has a rugged, industrial-grade metal housing, a 10-foot AC power cord, and a cord retention tray. It can be mounted horizontally and is UL60950_1 and CSA C22.2 certified by ETL and FCC Class A certified. A three-year warranty ensures that this PDU is free of defects in design, assembly, material or workmanship.

  • Metered Power Distribution Unit (PDU) – 200-240V AC, 20A maximum capacity (derated to 16 amps) is distributed to connected equipment.
  • Automatic Transfer Switch (ATS) – Dual 10FT NEMA IEC-320 C20 power cords provide redundant power sources to devices with single power supplies.
  • Power Redundancy – A and B power cords can be plugged into separate power sources to ensure continuous power access. Users can select their preferred source as the primary input.
  • Power Distribution – Ten (10) IEC-320 (8) C13 / (2) C19 outlets with unfiltered electrical pass-through are standard with the PDU20MHVIEC10AT PDU.
  • LCD Screen – The LCD provides real-time meter status for current (amperes), input and output voltages, power consumptions (kilowatts), and hardware/firmware versions.
  • SNMP/HTTP Card Slot – A SNMP/HTTP Card slot is available for the installation of an RMCARD202 or RMCARD203 (sold separately), providing remote monitoring, reporting, and event notifications, via Email, SMS Text, or SNMP Trap.
  • Upgradeable Hardware & LCD Firmware – Hardware and LCD firmware can be updated to the latest versions using the serial communication port.
  • Serial Communication Port – The metered ATS PDU comes with a serial port and cable to update/upgrade the hardware and LCD firmware.
  • Protocol Support – With installation of an RMCARD202 or RMCARD203 (sold separately), the metered ATS PDU includes protocol support for PowerPanel Business Edition, HTTP, TCP/IP, UDP, DHCP, and SNMP including SNMPv3, IPv4, IPv6, NTP, SMTP protocols.
  • Rack Mountable – Included rack mounting brackets allow for 1U horizontal rack installation.
  • Cord Retention Brackets – Included cord retention brackets keep power cords organized and securely plugged in.
  • Switchless Design – Designed without a power switch and circuit breaker (on most models) to prevent accidental power interruptions.
Input
Voltage 200V - 240V
Frequency 50Hz/60Hz
Maximum Input Current 20A (Derated to 16A)
On/Off Switch No
Plug Type 2 x IEC-320 C20
Plug Style Straight
Cord Length 10'
Output
Nominal Output Voltage 200-240V
Overload Protection (Each Bank) N/A
Outlets - # of Banks 1
Outlets - Total 10
Outlet Type IEC-320 C13 (8) / C19 (2)
Outlets - Front 0
Outlets - Rear 10
LCD Readout KW, Voltage, Amperage, Network Information, HW/FW Version
LED Indicators Input, Output Load
Management & Communications
SNMP / HTTP Remote Monitoring Yes, with optional RMCARD202 or RMCARD203
Connectivity Serial (RJ45)
Physical
Rack Size 1U
Form Factors Supported 1U Rackmount
Style Rackmount
Cord Retention Tray/Cord Organizers Yes
External Site Ground Pin Yes
Adjustable Mounting Brackets 1 set (L-long)
Dimensions (WxHxD) (in.) 17.05 x 1.75 x 9.3
Weight (lbs.) 7.5
Environmental
Operating Temperature 32 °F to 113°F / 0 °C to 45 °C
Operating Humidity 0% - 95% non-condensing
Storage Temperature 5°F to 113°F / -15°C to 45 °C
Maximum Operating Elevation 13,100 ft / 4,000 m
Maximum Storage Elevation 50,000 ft / 15,000 m
Certifications
Safety UL60950_1 certified by ETL (USA), CSA C22.2 (Canada), FCC Class B
Environmental RoHS Compliant
Warranty
Product Warranty 3 Years

Part Code:

PDU20MHVIEC10AT

Write a review

Cyber Power PDU20MHVIEC10AT 10-outlet (rear) metered

Cyber Power PDU20MHVIEC10AT 10-outlet (rear) metered

  • Metered Auto Transfer Switch (ATS) PDU
  • Digital Display (Load, Voltage, and KW)
  • 2 x IEC-320 C20 Plugs for Redundancy
  • 10 IEC-320 (8) C13 / (2) C19 Outlets (10 Rear)
  • 200-240V AC - 50/60Hz - 20-amp electrical capacity
  • 1U rack mount