Avocent PM2005V-406 0U Vertical 3-ph 32A 380/400/415V with IEC 309 32A, 21 C13 & 3 C19 ports

Vertiv Vertiv

New

Avocent PM2005V Power Distribution Unit
PM 2000 intelligent Power Distribution units (IPDUs) support outlet level metering and switching capability to provide datacenter professionals the tools they need to monitor, reduce, and manage their growing power consumption costs of IT equipment. Thresholds can be created to allow datacenter teams to know before problems occur and minimize downtime caused by overloaded circuits.


Call For Price And Availability

India: +91 895 697 6186
USA: +1 510 651 2205
Singapore: +65 9152 4003

[email protected]

Avocent PM2005V Power Distribution Unit
PM 2000 intelligent Power Distribution units (IPDUs) support outlet level metering and switching capability to provide datacenter professionals the tools they need to monitor, reduce, and manage their growing power consumption costs of IT equipment. Thresholds can be created to allow datacenter teams to know before problems occur and minimize downtime caused by overloaded circuits.

  • Outlet-Level, Phase-Level and Strip-Level Current/Voltage/Power Metering with Threshold/Alert Capabilities – Provides preemptive notification of any impending overload issues before they occur and simplifies the task of installing new equipment (Note- measurement resolution +/- %5)
  • On-Board Web Interface – Can be installed for direct access right out of the box or it can be configured as part of a larger integrated solution using the DSView 3 management software
  • IP and Serial Interface Options – Options to install by connecting directly to the network or save IP connections by using the serial interface to connect directly to Avocent appliances already connected to the network
  • Daisy Chaining – Saves the number of IP addresses or console/KVM ports that are required to manage all power distribution needs
  • Integration with DSView 3 Management Software – Single interface for management of IT equipment and PDUs simplifies mapping of outlets to servers and other equipment in order to reduce and minimize power cycling the wrong equipment
  • Integration with DSView 3 Software Power Manager Plug-In – Track historical trends to measure and monitor IT power consumption, capacity and cost in order to understand what issues exist and to make more informed decisions in the future
  • Electronic Overcurrent Protection – An added layer of protection that is activated in the event of minor overloads; during such events, outlets are turned off first instead of the primary overcurrent protection (OCP) tripping
  • Sequential Startup – Protects integrity of all upstream electrical infrastructure by staggering the inrush current draw of all plugged-in devices
  • Internal Temperature Sensor and Two Optional External Sensors – These sensors can measure environmental factors at several different points within the rack
Product Description Avocent PM2005V Power Distribution Unit
Device Type Power distribution unit - rack-mountable
Rack Size 0U
Input Voltage AC 380/400/415 V
Output Connector(s) 21 x power IEC 320 EN 60320 C13
3 x power IEC 320 EN 60320 C19
Dimensions (WxDxH) 5.6 cm x 167.6 cm x 8 cm
Weight 6.7 kg
Warranty 2 years warranty

Part Code:

PM2005V-406

Write a review

Avocent PM2005V-406 0U Vertical 3-ph 32A 380/400/415V with IEC 309 32A, 21 C13 & 3 C19 ports

Avocent PM2005V-406 0U Vertical 3-ph 32A 380/400/415V with IEC 309 32A, 21 C13 & 3 C19 ports

Avocent PM2005V Power Distribution Unit
PM 2000 intelligent Power Distribution units (IPDUs) support outlet level metering and switching capability to provide datacenter professionals the tools they need to monitor, reduce, and manage their growing power consumption costs of IT equipment. Thresholds can be created to allow datacenter teams to know before problems occur and minimize downtime caused by overloaded circuits.