Avocent PM2004V-401 0U Vertical 3-ph 16A 380/400/415V with IEC 309 16A, 21 C 13 & 3 C19 ports

Vertiv Vertiv

New

PM 2000 intelligent Power Distribution units (IPDUs) support outlet level metering and switching capability to provide datacenter professionals the tools they need to monitor, reduce, and manage their growing power consumption costs of IT equipment. Thresholds can be created to allow datacenter teams to know before problems occur and minimize downtime caused by overloaded circuits.


Call For Price And Availability

India: +91 895 697 6186
USA: +1 510 651 2205
Singapore: +65 9152 4003

[email protected]

PM 2000 intelligent Power Distribution units (IPDUs) support outlet level metering and switching capability to provide datacenter professionals the tools they need to monitor, reduce, and manage their growing power consumption costs of IT equipment. Thresholds can be created to allow datacenter teams to know before problems occur and minimize downtime caused by overloaded circuits.

  • Outlet-Level, Phase-Level and Strip-Level Current/Voltage/Power Metering with Threshold/Alert Capabilities – Provides preemptive notification of any impending overload issues before they occur and simplifies the task of installing new equipment (Note- measurement resolution +/- %5)
  • On-Board Web Interface – Can be installed for direct access right out of the box or it can be configured as part of a larger integrated solution using the DSView 3 management software
  • IP and Serial Interface Options – Options to install by connecting directly to the network or save IP connections by using the serial interface to connect directly to Avocent appliances already connected to the network
  • Daisy Chaining – Saves the number of IP addresses or console/KVM ports that are required to manage all power distribution needs
  • Integration with DSView 3 Management Software – Single interface for management of IT equipment and PDUs simplifies mapping of outlets to servers and other equipment in order to reduce and minimize power cycling the wrong equipment
  • Integration with DSView 3 Software Power Manager Plug-In – Track historical trends to measure and monitor IT power consumption, capacity and cost in order to understand what issues exist and to make more informed decisions in the future
  • Electronic Overcurrent Protection – An added layer of protection that is activated in the event of minor overloads; during such events, outlets are turned off first instead of the primary overcurrent protection (OCP) tripping
  • Sequential Startup – Protects integrity of all upstream electrical infrastructure by staggering the inrush current draw of all plugged-in devices
  • Internal Temperature Sensor and Two Optional External Sensors – These sensors can measure environmental factors at several different points within the rack

Inputs
Input frequency 50/60 Hz
Maximum input current per phase 16 A
 Colour
Colour of product Black
Technical details
Rack mounting 0U
Mounting Vertical
Weight & dimensions
Dimensions (WxDxH) 56 x 1676 x 80 mm
Weight 14.8 lbs
Operational conditions
Operating temperature range (T-T) 10 - 50 °C
Storage temperature range (T-T) -40 - 65 °C
Operating relative humidity range 20 - 80 %
Storage relative humidity range 5 - 95 %
Certificates
Certification UL, FCC, cUL, CE, VCCI, C-Tick, CB

Part Code:

PM2004V-401

Write a review

Avocent PM2004V-401 0U Vertical 3-ph 16A 380/400/415V with IEC 309 16A, 21 C 13 & 3 C19 ports

Avocent PM2004V-401 0U Vertical 3-ph 16A 380/400/415V with IEC 309 16A, 21 C 13 & 3 C19 ports

PM 2000 intelligent Power Distribution units (IPDUs) support outlet level metering and switching capability to provide datacenter professionals the tools they need to monitor, reduce, and manage their growing power consumption costs of IT equipment. Thresholds can be created to allow datacenter teams to know before problems occur and minimize downtime caused by overloaded circuits.