MOXA TCC-80/TCC-80I serial media converter

1 Review(s)
Moxa Moxa

New

The TCC-80/80I media converters provide complete signal conversion between RS-232 and RS-422/485, without requiring an external power source. The converters support both half duplex 2-wire RS-485 and full duplex 4-wire RS-422/485, either of which can be converted between RS-232’s TxD and RxD lines. In addition,the TCC-80/80I’s 15 kV ESD protection guards against damage from electrostatic discharge, and the TCC-80I is the world’s first high-speed, port-powered converter with 2.5 kV isolation.


Call For Price And Availability

India: +91 895 697 6186
USA: +1 510 651 2205
Singapore: +65 9152 4003

[email protected]

The TCC-80/80I media converters provide complete signal conversion between RS-232 and RS-422/485, without requiring an external power source. The converters support both half duplex 2-wire RS-485 and full duplex 4-wire RS-422/485, either of which can be converted between RS-232’s TxD and RxD lines. In addition,the TCC-80/80I’s 15 kV ESD protection guards against damage from electrostatic discharge, and the TCC-80I is the world’s first high-speed, port-powered converter with 2.5 kV isolation.

Port Power over RS-232
Automatic data direction control is provided for RS-485. In this case, the RS-485 driver is enabled automatically when the circuitry senses the TxD output from the RS-232 signal. This means that no programming effort is required to control the transmission direction of the RS-485 signal. Moreover, the TCC-80I’s patented LED port power indicator lets you check whether or not the TCC-80I is receiving enough power.

The RS-232 port of the TCC-80/80I is a DB9 female socket that can connect directly to the host PC, with power drawn from the TxD line. Regardless of whether the signal is high or low, the TCC-80/80I can obtain enough power from the data line. However, external power can be used if the handshake line is not available, if the serial cable is too long, or if the RS-232 device is a low power device. For external power, a 5 to 12 VDC power supply can be connected using an adaptor or a USB power cord.

Port Power Dissipation
The RS-232 port of the TCC-80/80I is a DB9 female socket that can connect directly to the host PC, with power drawn from the TxD line. Electrical 2.5 kV isolation for the TCC-80I is achieved with a photo coupler that transforms the electrical signal into light, and then re-transforms the light back into an electrical signal on the other side. In this way, the two electrical circuits are completely isolated from each other. This also protects the devices from ground loop currents, reduces damage caused by data loss, and prevents damage to the communication interfaces.

LED Port Power Indicator
It’s easy enough to test the serial device with a multimeter to determine that the serial device will provide enough power to the media converter. However, it’s even easier to let the TCC-80I test the device for you. Simply connect the TCC-80I to the device’s RS-232 port and set the SW4 switch to Test mode. If the patented port power LED indicator lights up, the TCC-80I is receiving enough power. If the LED does not light up, you will need to attach an external power source to the TCC-80I.

  • External power source supported but not required
  • Compact size
  • Converts RS-422, and both 2-wire and 4-wire RS-485
  • RS-485 automatic data direction control
  • Automatic baudrate detection
  • 15 kV serial ESD protection
  • Built-in 120-ohm termination resistors
  • 2.5 kV isolation (for TCC-80I only)
  • LED port power indicator
RS-232 Side
Connector DB9 female
Signals RS-232: TxD, RxD, GND
(Loop-back wiring: RTS to CTS, DTR to DSR and DCD)
 RS-422/485 Side
Connector Terminal Block or DB9 male
Signals (interface selected by DIP switch)
RS-422: TxD+, TxD-, RxD+, RxD-, GND
RS-485-4w: TxD+, TxD-, RxD+, RxD-, GND
RS-485-2w: Data+, Data-, GND
RS-485 Data Direction Control ADDC® (automatic data direction control)
 Serial Communication
Baudrate 50 bps to 115.2 kbps
ESD Protection 15 kV
Optical Isolation 2.5 kV rms for 1 minute (TCC-80I only)
 Physical Characteristics
Housing ABS + PC
Dimensions TCC-80/80I: 42 x 80 x 22 mm (1.65 x 3.15 x 0.87 in)
TCC-80-DB9/80I-DB9: 42 x 91 x 23.6 mm (1.65 x 3.58 x 0.93 in)
Weight 50 ± 5 g
Environmental Limits
Operating Temperature 0 to 60°C (32 to 140°F)
Storage Temperature -20 to 75°C (-4 to 167°F)
Ambient Relative Humidity 5 to 95% (non-condensing)
 Power Requirements
Source of Input Power RS-232 port (TxD, RTS, DTR) or power input jack
Input Voltage 5 to 12 VDC
Power Consumption TCC-80: 10 mA @ 5 V (with termination disabled)
TCC-80I: 20 mA @ 5 V (with termination disabled)
 Standards and Certifications
Safety UL 60950-1
EMC CE, FCC
EMI FCC Part 15 Subpart B Class B
EMS EN 61000-4-2 (ESD) Level 2,
EN 61000-4-3 (RS) Level 2,
EN 61000-4-4 (EFT) Level 2,
EN 61000-4-5 (Surge) Level 3,
EN 61000-4-6 (CS) Level 2,
EN 61000-4-8 (SFMF) Level 1
Green Product RoHS, CRoHS, WEEE
MTBF (mean time between failures)
Time 2,781,161 hrs
Database Telcordia (Bellcore), GB
 Warranty
Warranty Period 5 years
Details See www.moxa.com/warranty

Part Code:

TCC-80
TCC-80-DB9
TCC-80I
TCC-80I-DB9

Grade 
02/16/2016

Good product.

Good product. Highly recommended.

Write your review! !

Write a review

MOXA TCC-80/TCC-80I serial media converter

MOXA TCC-80/TCC-80I serial media converter

The TCC-80/80I media converters provide complete signal conversion between RS-232 and RS-422/485, without requiring an external power source. The converters support both half duplex 2-wire RS-485 and full duplex 4-wire RS-422/485, either of which can be converted between RS-232’s TxD and RxD lines. In addition,the TCC-80/80I’s 15 kV ESD protection guards against damage from electrostatic discharge, and the TCC-80I is the world’s first high-speed, port-powered converter with 2.5 kV isolation.