The TCC-120 and TCC-120I are RS-422/485 converters/repeaters designed to extend RS-422/485 transmission distance. Both products have a superior industrial-grade design that includes DIN-rail mounting, terminal block wiring, and external terminal block for power. In addition, the TCC-120I supports optical isolation for system protection. The TCC-120 and TCC-120I are ideal RS-422/485 converters/repeaters for critical industrial environments.
This product is no longer in stock
Availability date:
The TCC-120 and TCC-120I are RS-422/485 converters/repeaters designed to extend RS-422/485 transmission distance. Both products have a superior industrial-grade design that includes DIN-rail mounting, terminal block wiring, and external terminal block for power. In addition, the TCC-120I supports optical isolation for system protection. The TCC-120 and TCC-120I are ideal RS-422/485 converters/repeaters for critical industrial environments.
Serial Communication | |
Connectors | Terminal Block on both ends |
Baudrate | 50 bps to 921.6 kbps |
Signals | RS-422/485-4w: TxD+, TxD-, RxD+, RxD- RS-485-2w: Data+, Data- |
RS-485 Data Direction Control | ADDC® (automatic data direction control) |
ESD Protection | 15 kV for all signals |
Optical Isolation | 2 kV (TCC-120I only) |
Physical Characteristics | |
Housing | Metal |
Dimensions | 67 x 100.4 x 22 mm (2.64 x 3.93 x 0.87 in) |
Weight | 148 ± 5 g |
Environmental Limits | |
Operating Temperature | -20 to 60°C (-4 to 140°F) |
Storage Temperature | -20 to 75°C (-4 to 167°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
Power Requirements | |
Source of Power Input | Power input jack |
Input Voltage | 12 to 48 VDC |
Power Consumption | TCC-120: 65 mA @ 12 V TCC-120I: 180 mA @ 12 V |
Voltage Reversal Protection | Protects against V+/V- reversal |
Over Current Protection | Protects against two signals shorted together |
Standards and Certifications | |
Safety | UL 60950-1 |
EMC | CE, FCC |
EMI | FCC Part 15 Subpart B Class B |
EMS | EN 61000-4-2 (ESD) Level 2, EN 61000-4-3 (RS) Level 2, EN 61000-4-4 (EFT) Level 2, EN 61000-4-5 (Surge) Level 2, EN 61000-4-6 (CS) Level 2, EN 61000-4-8 (PFMF) Level 1 |
Green Product | RoHS, CRoHS, WEEE |
MTBF (mean time between failures) | |
Time | 1,949,025 hrs |
Database | Telcordia (Bellcore), GB |
Warranty | |
Warranty Period | 5 years |
Details | See www.moxa.com/warranty |
Part Code:
TCC-120
TCC-120I
Good product.
Nice product to use, i haven't seen any issue using it so far.