Server Technology CLG-24V4J421A9 Smart PDU

ServerTech ServerTech

New

The Sentry POPS Smart PDU CSG-24V4 400V 16/32A is a mixed outlet Rack Power Distribution Unit with the network and serial-based power monitoring and alerting capabilities of the Smart Cabinet PDU plus the ability to monitor.


Call For Price And Availability

India: +91 895 697 6186
USA: +1 510 651 2205
Singapore: +65 9152 4003

[email protected]

The Sentry POPS Smart PDU CSG-24V4 400V 16/32A is a mixed outlet Rack Power Distribution Unit with the network and serial-based power monitoring and alerting capabilities of the Smart Cabinet PDU plus the ability to monitor:

  • Current Load (A)
  • Voltage (V)
  • Power (W)
  • Apparent Power(VA)
  • Crest Factor and 
  • Power Factor

Combine the Sentry POPS Smart Rack PDU with the Sentry Power Manager (SPM) software tool to cluster outlets and gain power usage information across multiple Rack PDU's individual IP address.

The Sentry Power Manager (SPM) provides power distribution unit power (kW and kW-h) monitoring and environmental monitoring across all Sentry PDU's within the network. Receive email alerts when power or environmental conditions exceed thresholds. Assign users specific access rights to designated outlets or groups.

  • Per Outlet Power Sensing

Power monitoring and information per individual outlet/device. Information includes: Current Load (A), Voltage (V), Power (kW), Apparent Power (VA), Crest Factor and Power Factor per outlet. kW and kW-hour power information that can be utilized for billing, power monitoring, trending and power reports.

  • Establish efficiency ratings- PUE and DCIE

Power information generated can be used to calculate PUE and DCIE. These power ratings have been established by the Green Grid to gauge efficiency.

  • Control Conditions for Alarm Notification

Conditions for SNMP traps can be regulated for Status, Changes, Load, Temperature and Humidity.

  • HTTP/HTTPs Web Configuration & Control

Use the Sentry Web interface to configure each unit, including network settings, outlet naming & grouping, SNMP traps for environmental & power thresholds and firmware updates. Also use the Web interface to monitor key values, including amperage load(s), temperature/humidity and other environmental conditions. SSL security provides a secure HTTPs connection.

  • SNMP Management & Event Notification

The Sentry family of products supports the Simple Network Management Protocol (SNMP). This allows network management systems to use SNMP requests to retrieve information (Smart and Switched CDUs) and control power for the individual outlets (Switched CDUs). The Sentry includes an SNMP v1 agent supporting standard MIB I and MIB II objects. A private enterprise MIB extension (Sentry3 MIB) is also supported to provide network access power control. SNMP traps can be generated for various events, including Input Current Load Thresholds (min & max), Temperature Thresholds (min & max), Humidity Thresholds (min & max), water indication, closed contacts (cabinet doors open/close), as well as notification of any time an outlet status is changed (on/off) for Sentry Switched CDUs.

  • Add a Second Tower

Connect an Expansion Cabinet power distribution unit to any POPS Cabinet PDU to control two power input circuits and manage outlets (individual or groups) under 1 IP address - our exclusive strategy for managing dual power-supply servers.

  • Zero U Enclosure

A vertical enclosure that occupies Zero Vertical U of rack space in the equipment cabinet. It mounts on the back rails or in the cavity space of the cabinet.

  • Secure Access - SSH or SSL Protection

Secure Shell (SSH), known as Secure Socket Shell, is a Unix-based command interface and protocol for securely getting access to a network access device. Sentry supports SSHv2. Secure Sockets Layer (SSL) is a commonly-used protocol for managing the security of a message transmission on the Internet. SSL is an integral part of most Web browsers (clients) and Web servers. Sentry supports SSLv3/TLSv1.

  • Integrated Temp/Humidity Probes

Two (2) RJ-style connectors located on the face panel of the PDU's enclosure provide support for two (2) Integrated Temperature & Humidity Probes with ten-foot (10') cables provide real-time measurements in the data center cabinet.

  • Firmware Flash Upgradeable

Access new firmware updates via FTP for new firmware features and code releases. An update to the firmware does not affect the status of the power outlets.

  • LDAP/LDAPS

The sentry family of products supports Lightweight Directory Access Protocol (LDAP) Version 3 including LDAPS (LDAP over TSL/SSL). This support enable authentication with LDAP servers; user accounts do not need to be individually created locally on each Sentry device.
This allows administrators to pre-define and configure (in each Sentry product, and in the LDAP server) a set of necessary LDAP groups, and access rights for each. User's access rights can then be assigned or revoked simply by making the user a member of one or more pre-defined Sentry LDAP groups. User account can be added, deleted, or changed in the LDAP server without any changes on individual Sentry products.
Sentry LDAP support has been tested in the following environments:
- Microsoft Active Directory (MSAD)
- Novell eDirectory (eDir)
- Open LDAP

  • Load Sense

Individual input current monitoring ("Load Sense") provides real-time power measurement of the load in amps on each power inlet, accessible via firmware interface.

  • RS-232 Control

Serial control via any device with a bi-directional serial port, including a PC, laptop, KVM switch, Console Port Access switch, or terminal server.

  • 24-Character Outlet Receptacle Names

Use the firmware interface (Web or serial) to edit individual outlet receptacles. Identify each receptacle with the device's serial number, IP address, asset allocation #, department or any other method to individually name outlets.

Sentry Cabinet PDU Specifications
Item # Available Input
Voltages
Rated Amperage Available Input Cord Outlets Dimensions
(L x W x D)
CSG-24V4
CSG-24V4J421A9
CLG-24V4J421A9*
400V 3-Phase Wye, 50/60Hz 16 A IEC Red 6Hr 3P+N+G Plug, 10'(3m), Bottom/Frt Cord (12) IEC 60320/C13
(12) IEC 60320/C19
1794 x 44 x 89 mm
(70.6 x 1.75 x 3.50 in.)
CSG-24V4K425A9
CLG-24V4K425A9*
400V 3-Phase Wye, 50/60Hz 32 A IEC Red 6hr 3P+N+G Plug, 10' (3m), Bottom/Frt Cord (12) IEC 60320/C13
(12) IEC 60320/C19
1794 x 44 x 89 mm
(70.6 x 1.75 x 3.50 in.)
* CLG refers to the Expansion Module

Part Code:

CLG-24V4J421A9

Write a review

Server Technology CLG-24V4J421A9 Smart PDU

Server Technology CLG-24V4J421A9 Smart PDU

The Sentry POPS Smart PDU CSG-24V4 400V 16/32A is a mixed outlet Rack Power Distribution Unit with the network and serial-based power monitoring and alerting capabilities of the Smart Cabinet PDU plus the ability to monitor.