As part of its NRGence line, ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage. The NRGence PE5340s is an intelligent PDUs that contains 40 AC outlets and is available in IEC or NEMA input configurations. The PE5340s provides secure, centralized, intelligent, power management of data center IT equipment (servers, storage systems, KVM switches, network devices, serial data devices, etc.), as well as the ability to monitor the center's health environment via sensors
This product is no longer in stock
Availability date:
As part of its NRGence line, ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage.
The NRGence PE5340s is an intelligent PDUs that contains 40 AC outlets and is available in IEC or NEMA input configurations. The PE5340s provides secure, centralized, intelligent, power management of data center IT equipment (servers, storage systems, KVM switches, network devices, serial data devices, etc.), as well as the ability to monitor the center's health environment via sensors *.
NRGence eco PDUs offer remote power control combined with real-time power measurement - allowing you to control and monitor the power status of devices attached to the PDUs, either at the PDU device or bank level, from practically any location via a TCP/IP connection **.
The eco PDU also offers comprehensive power analysis reports providing precise measurements of current,voltage, power and watt-hour in a real-time display.
Installation and operation is fast and easy: plugging cables into their appropriate ports and user-friendly browserbased configuration and management is all that is entailed. Since the eco PDU firmware is upgradeable over the Net, you can stay current with the latest functionality improvements simply by downloading updates from our website as they become available.
NRGence eco PDUs support any 3rd party V1, V2, V3 SNMP Manager Software and NRGence eco Sensors (eco PDU Manager Software). Eco Sensors provides you with an easy method for managing multiple devices, offering an intuitive and user-friendly Graphical User Interface that allows you to configure a PDU device and monitor power status of the equipment connected to it
Function | PE5340sB | PE5340sG |
Electrical | ||
Nominal Input Voltage | 100 – 240 VAC | |
Maximum Input Current | 30A Max ; 24A (UL de-rated) | 32A Max |
Input Frequency | 50-60 Hz | |
Input Connection | 1 x NEMA L6-30P | 1 x IEC60309 32A |
Input Power | 6240 VA(Max) 4992 VA (UL de-rated) | 7360 VA(Max) |
Outlet Type | Total : 40 x IEC320 C13 Bank1 : Outlet 1 – 20 ; 20 x C13 Bank2 : Outlet 21 – 40 ; 20 x C13 |
|
Nominal Output Voltage | 100 – 240 VAC | |
Maximum Output Current (Outlet) | C13 : 10A (Max) 12A(UL de-rated) | C13 : 10A (Max) |
Maximum Output Current (Bank) | 15A(Max) 12A (UL de-rated) | 16A(Max), TUV De-rated 15A(Max) |
Maximum Output Current (Total) | 30A(Max) 24A (UL de-rated) | 32A(Max). TUV De-rated 30A(Max) |
Breakers | 2 x 16A UL489 breaker | 1 x 16A UL489 breaker |
Metering | Per Outlet Level Current, Voltage, VA, PF, KWh Monitoring | |
Outlet Switch | None | |
Environment Sensor Port | 2 | |
Metering Accuracy | Voltage Range: 100VAC ~ 250VAC +/-1% Power Range: 100W ~ 5000W +/- 2% Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1% |
|
Mechanical | ||
Dimension (H x W x D) | 135.9 x 6.6 x 4.4 cm | 135.9 x 6.6 x 4.4 cm |
Weight | 4.58 kg | 4.58 kg |
Power Cord Length | 1.6 m | |
Environmental | ||
Temperature (Operating / Storage) | 0 – 50°C / -20 – 60°C | 0 – 40°C / -20 – 60°C |
Humidity (Operating & Storage) | 0 – 80% RH, Non-Condensing | |
Compliance | ||
EMC Verification | FCC Part 15 Class A, Others by Reuest | CE, Others by Request |
Safety Verification | TUV-CB, Others by Reuest | CE-LVD,TUV-CB, Others by Request |
Part Code:
PE5340s